Blog

EMC CX3 CX4 VNX Factory Reset

Power down array Remove SPB Connect serial port to SPA 9600/8n1 On the alphabet press Cntrl-C NOTE: This was done on a CX4-960 array. Utility version 04.30.000.5.506. Your screens might be different. ABCDabcEabcdefFabcdefGabcdefHIabcd > JabcKLMNOabcdePQabRabcSabcTUabVabWXYabZAABBCCabcDDabcEEabcFFabcGGabHHIIJJKKLLMMNNabcOOabcPPabcQQabcRRabSSTTUUVVWWXXYYabcZZabcAAAabcBBBabcCCCabDDDEEEFFFGGGHHHIIIJJJabcKKKabcLLLabcMMMabcNNNabcOOOPPPQQQabRRRSSSabcdefTTTabcdefUUUabVVVWWWXXXYYYZZZAAAABBBBabcCCCCabcDDDDabcEEEEabcFFFFGGGGHHHHabcIIIIJJJJKKKKLLLLMMMMNNNNOOOOPPPPQQQQ ************************************************************ * Extended POST Messages ************************************************************ INFORMATION: MCU Operating mode changed from Enginuity to Clariion ************************************************************ EndTime: 03/30/2016 00:39:16 Type…
Read More

Create EMC recovery drive using existing array

Below are the steps to create a blank recovery drive without a utility partition or a PSM. **** NOTE Do this at your own risk if you mess this up you could lose all your data. This is just a normal disclaimer and I've never had that issue. But I warned you. *** Power down…
Read More

VMWare/EMC VDP 6.1 recover crash

If your VDP server will not start after a power off event. Connect to the server https://vdp ip:8543/vdp-configure/ the management service status shows not running. You will need to recover the vdp database. Run this command to rollback the database. dpnctl start mcs --force_mcs_restore
Read More

ESXi Windows Server RDM Disks Offline after reboot

After rebooting a virtual machine the machine comes up with all disks but C: offline. To fix: "diskpart" "san" says policy offline type "san policy=OnlineAll" * Note this seems to only happen if you assign disks to other then the primary SCSI bus that the OS is on. Reading help san explains why this is…
Read More

EMC PPP serial connection Windows 7/8/10

Create a new PPP dialup connection in Networking. Doesn't matter what you put for the phone number. Close out of that wizard and navigate to %appdata%\Microsoft\Network\Connections\Pbk Edit the rasphone.pbx file in notepad Change Type=1 to Type=3 Dial with login clariion/clariion!
Read More

EMC RemotelyAnywhere Windows 10

EMC RemotelyAnywhere doesn't work well in any browser but old firefox or internet explorer. Windows 10 only has Edge browser... Nope. Start run then type iexplore hit enter and you have Internet Explorer Note first you should go start then type java and configure java Go to the security tab and add a new site…
Read More

Microsoft Exchange 2013 Issue

Process Microsoft.Exchange.Directory.TopologyService.exe (PID=2092) Forest XXX. Topology discovery failed, error details No Minimal Required Number of Suitable Directory Servers Found in Forest XXX Site XXX and connected Sites.. Problem: This issue appeared when we added a tree domain to the forest. For some reason 2 AD controllers weren't enough. Solution: As administrator edit Microsoft.Exchange.Directory.TopologyService.exe.config file in…
Read More

Start and Stop VMWare virtual machines using powershell

Install PowerCLI from the VMWare support site Create file shutdown.ps1 Add-PSSnapin Vmware* Connect-VIServer -server XXX -user XXX@vsphere.local -password XXXX $vmservers = Get-VM | Where-Object { $_.Name -like 'VICI-*' -and $_.PowerState -eq 'PoweredOn' } $vmservers | select Name | export-csv c:\temp\viciservers.csv -NoTypeInformation $vmservers | Stop-VMGuest -Confirm:$false Create file startup.ps1 Add-PSSnapin Vmware* Connect-VIServer -server XXX -user XXX@vsphere.local…
Read More

How to PXE boot an EMC CX4 SAN

Setup a DHCP and PXE server. Grab a copy of CXClear and install it. (Note this is for the CX3 and older arrays) Open explorer to C:\Program Files (x86)\EMC\TsgTools\CXClear\clariion-app Copy all the files to the tftp root directory on your host or you can run the tftpd client Connect serial port to the EMC array…
Read More

IBM Power HMC VirtualBox Install

Download the iso image (I used this one HMC_Recovery_V8R830_1.iso) Setup new VM I used linux 2.6 and 150gb hard disk For the HD controller change it from SATA to IDE Memory 1gb Network bridged Intel 1000 MT Server Edit the .vbox file and add the following: Thats it boot and install.
Read More

Using Rancid config manager with Brocade FabricOS

**** Note this does not work in the version of rancid instead use the built in foundry template. **** First get rancid working Download HowTo These instructions assume installation in /usr/local/rancid and running as user rancid Download these files brocaderancid and brocadelogin Put in bin directory and set permissions and user same as clogin Create…
Read More

Cisco Switch to Brocade Turbo Iron, Trunk Channel Group

Working configuration for trunking a channel group to Brocade TurboIron Brocade TurboIron-X24 Version 08.0.01cT203 ------------ vlan 2 tag e 25 e 26 int e 25 port-name LAS-05 dual-mode 1 ip-port-mtu 1500 spanning-tree 802-1w admin-pt2pt-mac link-aggregate configure key 10001 link-aggregate active pvst-mode int e 26 port-name LAP-05 dual-mode 1 link-aggregate configure key 10001 link-aggregate active pvst-mode…
Read More

Cisco ASA to Switch arp incomplete

The ASA 5510 v9.0(3) does not support untagged vlan packets. What if you want to put a port on vlan 1??? Set the interface on the switch to another native vlan this will force vlan 1 to be tagged. switchport trunk native vlan 100 Thats it and the asa will start responding!
Read More